Call+84 28 3773 4498   info@phanta.com.vn   







»
Voyage Data Recorder (VDR)

The new standard: PT9 Ninety

IMO resolution MSC.333(90): On ships which are built on or after July 1, 2014, underwater locating devices must ensure a regulatory transmission time of at least 90 days.


Description

Minimum Performance Standards
SAE AS8045A
IEC 61996-1 (2013-05) Ed. 2.0
This standard incorporates the applicable parts of the performance standards included in IMO Resolution MSC.333(90).
Dimensions
Length 98mm (3,85 inch), Diameter 33mm (1,3 inch) same as PT9 C-Proof
Weight: 187 g (6.6 ounces)
Power source
Self-contained, lithium battery (field replaceable)
Non restricted for transport (UN3091/PI970)
Operating Details
Actuation: Automatically by both, fresh and salt water, at all depths from 0.15 m/0.5 ft to 6096 m/20000 ft within 4 hours after immersion
Operating Temperature: -2 °C (28 °F) to +38 °C (100 °F).
Radiation Pattern: 80% of a spherical pattern
Operating Frequency: 37.5 ± 1 kHz
Operating Life: 90 days