BIO-S-CAPE
Emergency
Escape
Breathing
Apparatus
EN
1146 Duration
10 minutes or 15 minutes
PROTECTION
RESPIRATOR
FENZY is proud to launch its latest innovative type of Emergency Escape Breathing Apparatus Two
breaking through innovations
make the BIO-S-CAPE
the safest EEBA of his generation: TECHNICAL
DESCRIPTION : Consisting
of : Carrying bag , Reducer with
automatic activated air flow (AAAF),
Hood with automatic half mask
adjustment, Alarm whistle, 2 litres steel cylinder. The BIO-S-CAPE fulfils
EN 1146 test Memorandum as
its Revised Version to be published within 2002. HOOD: Working
principle: The
breathable air feed by the reducer to an inflatable cushion inside the hood,
is then breathed through an inner half mask . Air is expelled outside the hood
through a calibrated exhalation valve Hood
Material :
Made of a triple layer of bright color air and waterproof flame
retardant material. Inner
half mask :
Made
of synthetic material, medium size, fully adaptable and fitted with 2 inhalation
valves NEW
: FULLY AUTOMATIC HALF MASK DONNING
The
donning of the Inner Half-Mask is performed automatically thanks to the
inflatable air cushion integrated in the neck (patent pending). It offers the
best breathing comfort, a hand free donning and the highest safety level. Exhalation
valve :
Spring
loaded to ensure a slight positive pressure in the hood Neck
Seal :
Soft synthetic rubber (non-allergic) to reach perfect tightness and
full comfort. Vision
:
Flame retardant material with large vision field. AIR
REDUCER: Working
principle: The
air contained in the cylinder is released immediately at the opening of the
bag , a
constant flow is then inflating the hood. A whistle will indicate imminent end
of the air reserve . Reducer
materials:
High-pressure
brass, nickel-plated. Reducing
system:
Piston/spring type, built-in safety valve Starting
:
Fully automatic triggering device at the opening of bag cover. Working
pressure :
300 bar (but delivered with a 200 bar connector). Airflow
:
Adjustable by flow limitation screw (by authorized persons only) Pressure
Gauge :
Constant reading, fixed on the reducer, visible all the time Air
filling :
Through EN 144-2
G-5/8 200 bar Air
Moisture :
Vacuum valve to vacuum the cylinder before filling if necessary NEW
: WHISTLE CLOSE TO THE EAR WITH NO AIR CONSUMPTION ! Whistle
:
Extremely loud end of use alarm , located close to the ear. The whistle
HAS NO air consumption ( air is re-circulated in the hood) CARRYING
BAG
:
Strong
PVC, orange color, with quick opening through VelcroÒ
Large
adjustable neck strap, waist strap on option Integrity
seal (which is broken when the EEBA is used) Large
window to check the cylinder pressure and the starting needle DURATION
:
10 minutes in accordance with EN 1146 A
15 minutes version is also available ( needed for longer escape routes)
|